Nothing to loft
CadQuery 2.8.0 loft found no pending section wires, faces or vertices to build through.
The loft operation has no usable cross-sections. An empty Workplane establishes coordinates but does not create a section profile.
No profiles were created before loft, or the intended profiles were not retained on the operation chain. One profile produces a different diagnostic, More than one wire or face is required. A loft requires enough usable sections and their intended spatial placement.
import cadquery as cad
result = cad.Workplane("XY").loft()
Create the two intended closed section profiles on the same modelling chain, separated by the required 5 mm height, then loft through them.
```python
import cadquery as cad
result = (cad.Workplane("XY").circle(3)
.workplane(offset=5).circle(2).loft())
```